2. When the plastic storage tank stores chemicals, there should be a good drainage trench and dilution device around the site.
3. As the plastic storage tank is inevitably forming a spherical crown at the bottom of the tank during molding, the base should be made into a spherical cap shape similar to the shape of the bottom, and on the basis of the level, it is not necessary to use sand to lay the bottom corresponding to the tank. Ball-shaped, suitable for direct exposure to sunlight when used in open air, extending service life.
4. When installing large-size plastic storage tanks, pay attention to safety and try to use a crane. If you do not know the method, please contact us.
5. After the plastic tank is installed, check the sealing performance of the interface before use. You can add liquid to the interface to see if it leaks. Storage tanks containing chemical liquids are best tested by water leaks to prevent significant losses.
6. Pipes connected to the lower part of plastic storage tanks or flanges should be perpendicular to the wall of the tank. It is better to use a soft connection to avoid the uneven expansion of the upper and lower walls of the tank after the tank is filled with liquid, resulting in leakage due to joint damage and serious damage to the joints. And barrel body.
7. When the liquid inlet is higher than the bottom of the tank, the liquid inlet should be bent toward the tank wall so that the liquid can fall along the tank wall and reduce the impact on the bottom.
8. The plastic storage tank has been formed with an integral one-step reinforcement ring. If necessary, a metal reinforcement sleeve may be used to limit the expansion deformation of the barrel to avoid bottom expansion.
9. When installing heavy accessory equipment such as mixers on the bucket, or when people are required to work on the top of the tank and the top of the tank cannot bear the weight of the person, please do another shelf or ladder and pay attention to the safety of the work.
10. In the case where the liquid level cannot be controlled, an overflow port should be installed to prevent liquid from overflowing from the manhole and causing unnecessary injury.
11. When the flow of liquid and liquid is large, the exhaust pipe of the corresponding flow should be installed. Related other products: Condenser mist Absorption Tower